stroj

ISO/UTS reductions


These reductions enable transition from an ISO steep cone to UTS tool holder.

Reductions are manufactured in compliance with valid standards.

A UTS test bar is recommended to be purchased for every reduction. The bar is fitted with an edge with evaluation parameters of X coordinate (tool diameter) and Z (tool length).

These specifications determine the beginning of reduction coordinates.

The coordinates are checked by a calibration laboratory.

Calibrated test bar has two functions.

First, it ensures very accurate setting of the coordinate beginning, based on real dimensions situated to the tool setting area.

Second, it represents a test bar – primary standard, ensuring connection to national standards when assuring ISO standard functions.

If a reduction is used, the effective length of Z coordinate is shortened. With ISO/UTS reductions the shortening varies, see the following table:

 

Reduction

Shortening (mm)

ISO 40 / UTS 32

40

ISO 40 / UTS 40

40

ISO 40 / UTS 50

60

ISO 50 / UTS 32

40

ISO 50 / UTS 40

40

ISO 50 / UTS 50

60

ISO 50 / UTS 63

60